MODEL FS 21
NON-CATALYTIC UNIT
FEATURES
PREPARATIONS INSTALLATION
OPERATION MAINTENANCE SAFETY
B
u
c
k
S
t
o
v
e
SAFETY NOTICE
IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY
RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION
INSTRUCTIONS. CONTACT THE AUTHORITY HAVING JURISDICTION
(SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTION BUREAU, etc.) CONSULT BEFORE INSTALLATION TO
DETERMINE THE NEED TO OBTAIN A PERMIT. KEEP THESE
INSTRUCTIONS FOR FUTURE USE.
TESTED AND LISTED BY: ITS/WARNOCK HERSEY, MIDDLETON, WI
MANUFACTURED BY NEW BUCK CORPORATION
200 ETHAN ALLEN DRIVE
P.O. BOX 69
SPRUCE PINE, N.C. 28777
www.buckstove.com
Revised July 2010
Vista de pagina 0
1 2 3 4 5 6 ... 32 33

Indice de contenidos

Pagina 1 - NON-CATALYTIC UNIT

MODEL FS 21 NON-CATALYTIC UNIT FEATURES PREPARATIONS INSTALLATION OPERATION MAINTENANCE SAFETY Buck Stove

Pagina 2

Page 8 HOW TO LOCATE CHIMNEY EXIT AND INSTALL Residential Installation B. Vertical Wall Exit using (6" Single Wall minimum 24 ga. blued

Pagina 3 - TABLE OF CONTENTS

Page 9 B. Vertical wall exit using (6" Single wall minimum 24 ga. blued or black pipe with elbow and any listed 2100° UL 103 HT. TYPE Chimney

Pagina 4 - WARNING

Page 10 HOW TO LOCATE CHIMNEY EXIT AND INSTALL Residential and Mobile Home Installation C. Vertical Exit using (6" DVL Close Clearance pip

Pagina 5 - SECTION I

Page 11 NOTE: All clearances are to combustibles with optional close clearance shields and pipe shield, using DVL Close Clearance pipe, and minimum

Pagina 6 - / MOBILE FREESTANDING

Page 12 HOW TO LOCATE CHIMNEY EXIT AND INSTALL Residential and Mobile Home Installation D. Vertical Wall Exit using (6" DVL Close Clearance

Pagina 7

Page 13 D. Vertical wall exit using (6" DVL Close Clearance pipe with elbow and any listed 2100° UL 103 HT. TYPE Chimney and Listed 2100° UL

Pagina 8 - CHIMNEY

Page 14 OUT SIDE AIR INSTALLATION Select an installation location that will give the best airflow from the front of the heater to the remainder of

Pagina 9

Page 15 UNDER SIDE OF MOBILE HOME FLOOR Figure 10B OUTSIDE AIR DUCT FLOOR PROTECTOR PAD OUTSIDE AIR DUCT THROUGH FLOOR WHEN MOBILE HOME IS NOT UND

Pagina 10

Page 16 FINAL CHECK 1. Recheck the specified clearances. 2. Remove all foreign material from the firebox area. 3. Open the primary air draft. 4.

Pagina 11

Page 17 ALCOVE INSTALLATION AND CLEARANCES Select an installation location that will give the best airflow from th

Pagina 13 - BUCK STOVE

Page 18 Floor Protection: Floor protection must be 3/8” minimum thickness non-combustible material or equivalent. How to use alternate materials and

Pagina 14 - Page 12

Page 19 HOW TO LOCATE CHIMNEY EXIT AND INSTALL Alcove Installation Vertical Exit using (6" DVL Close Clearance pipe and any Listed 2100° UL 10

Pagina 15

Page 20 ALCOVE INSTALLATION AND CLEARANCES Vertical exit using (6" DVL Close Clearance pipe, and any listed 2100° UL 103 HT. TYPE Chimney).

Pagina 16 - CAUTION

Page 21 FINAL CHECK 1. Recheck the specified clearances. 2. Remove all foreign material from the firebox area. 3. Open the primary air draft. 4.

Pagina 17 - Figure 10B

Page 22 Installation of (Optional) Close Clearance Shields and Pipe Shield 1. Taking close clearance side shields, hold up to side of stove leav

Pagina 18 - FINAL CHECK

Page 23 OPERATION This section of the manual is to help you get the maximum efficiency and maximum smoke (particulate) reduction from your heate

Pagina 19 - Page 17

Page 24 ASH REMOVAL INSTRUCTIONS (3) DUMP CHANNEL. SWEEP ASHES INTO ASHASH DUMP TOP LID ANDREAR OF HEATER. OPENDUMP TOP LID IN RIGHTFIRE BOX. LOCA

Pagina 20 - Floor Protection:

Page 25 OPTIONAL MOTOR ASSEMBLY KIT INSTALLATION INSTRUCTIONS STEP 1. REMOVE ACCESS DOOR PANEL LOCATED AT BOTTOM OF UNIT. YOUR MOTOR ASSEMBLY CO

Pagina 21 - Alcove Installation

Page 26 STEP 1 STEP 2 STEP 3 WIRE DIAGRAM

Pagina 22 - AND CLEARANCES

Page 27 1 - MOTOR (NON-CAT) 1 - MOTOR BRACKET 6 - #10 - 16 X 1/2” HEX HEAD 1 - #6 - 32 X 1/2” SLOT HEAD SCREW 5 - 1/8” X 1” BLACK FLAT GASK

Pagina 23

TABLE OF CONTENTS Important Instructions ...

Pagina 24

Page 28 WOOD HEATER SAFETY Certain safety hazards are inherent in any wood heater installation. You should be aware of these so that a safe an

Pagina 25 - SECTION IV

Page 29 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Sluggish Heater Obstruction in chimney Check for and remove obstruction Wet or uns

Pagina 26 - INSTRUCTIONS

Page 30 NEW BUCK CORPORATION (NBC) "LIMITED WARRANTY" FOR THE BUCK STOVE PLEASE READ THIS WARRANTY CAREFULLY PRODUCTS COVERED This warra

Pagina 27 - SECTION V

If for any reason you are dissatisfied with the suggested procedures, you may contact us in writing at: New Buck Corporation Customer Service D

Pagina 28 - WIRE DIAGRAM

Page 2 INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS MODEL FS 21 READ THIS FIRST IMPORTANT INSTRUCTIONS  The New Buck Corp. non-cataly

Pagina 29 - Page 27

Page 3 INTRODUCTION Your new MODEL FS 21 is a non-catalytic unit designed to meet the most stringent emissions standards without the use of a cata

Pagina 30 - SECTION VI

Page 4 RESIDENTIAL / MOBILE FREESTANDING INSTALLATION AND CLEARANCES Select an installation location that will give the best airflow fro

Pagina 31 - SECTION VII

Page 5 Floor Protection: Floor protection must be 3/8” minimum thickness non-combustible material or equivalent. How to use alternate materials and

Pagina 32 - NEW BUCK CORPORATION (NBC)

Page 6 PREPARING THE ROOM HEATER LOCATION 1. Select an installation location that will give the best airflow from the front of the heater to the re

Pagina 33 - OWNER REGISTRATION CARD

Page 7 A. Vertical exit using (6" Single wall minimum 24 ga. blued or black pipe and any listed 2100° UL 103 HT. TYPE Chimney) Without o